Released versions:
Click here for the release note from V1.00 to V3.00
Priority Rank Level
🇦 : Recommended to apply |
Version 3.31
Release date: Sept 28, 2023
New Features / Improvements
Extended the storage period of count data from 92 to 732 days. 🇺
Resolved Issues
Corrected the response to the CGI command of "2.4. Get the meta information(JSON files)" on AI-VMD External Interface Specification【C0323】🇺
Version 3.30
Release date: July 31, 2023 - Download the latest software
New Features / Improvements
Supports new cameras 🇺
WV-X35402-F2LM / X35402-F2L / S35402-F2L / S35402-F2LG / S35402-F2L1
WV-S32402-F2L / S32402-F2LG / S32402-F2L1
WV-X35302-F2LM / X35302-F2L / S35302-F2L / S35302-F2LG / S35302-F2L1
WV-S32302-F2L / S32302-F2LG / S32302-F2L1
WV-S1136A / S1536LA / S1536LA-B / S1536LNA / S1536LNA-B / S1536LNSA / S1536LTA / S1536LTNA
WV-S2136A / S2136A-B / S2136GA / S2136GA-B / S2136LA / S2136LA-B / S2136LGA / S2136LGA-B
WV-S2236LA / S2236LA-B / S2236LGA / S2236LGA-B / S2536LA / S2536LGA / S2536LGNA / S2536LNA
WV-S2536LTA / S2536LTNA / WV-S71300A-F3
*"Compatibility list for extension software" (Control number: C0103) will be updated on Technical Information.Improved the setting field on the demo screen. 🇺 View details
Improved the process to reflect the application settings imported via i-PRO Configuration Tool (iCT) so that the camera does not need a reboot to reflect changes. 🇺
Improved the process to reflect the setting changes of [AI-VMD information addition] and [Additional information type] so that reloading the setting window is not required anymore. 🇺
Version 3.21
Release date: March 31, 2023
New Features / Improvements
Supports 0.5s, 1s, 2s, 3s, and 4s of the [Alarm deactivation time] on camera’s setting. 🇺
Version 3.20
Release date: February 27, 2023
New Features / Improvements
Supports setting of detection line and detection area name. 🇺 View details
Added [Judgement of movement distance]* on the [Detailed setting] window to set the alarm threshold.
*Selectable items: Off/ Low/ Medium/ High 🇺 View detailsAdded [Measure score] on/off setting on the demo window to measure and display the maximum and minimum detection score of an object. 🇺 View details
Improved the visibility of setting window by removing AI frame and locus display from the image. 🇺
Added 5sec, 10sec and 15sec to the [Transmission interval] options of MQTT transmission and HTTP transmission settings. 🇺 View details
Improved to send detection score to i-PRO Active Guard. This enabled the deteciton score display on i-PRO Active Guard.
Updated external interface specifications.
For details, refer to "AI-VMD External Interface Specification【C0323】" on Technical Information.Supports "Perpendicular angle mode" for multi-directional cameras. 🇺 View details
Version 3.10
Release date: September 26, 2022
New Features / Improvements
Supports MQTT alarm transmission. 🇺 View details
"MQTT alarm notification" setting has been added to the [6.Alarm setting] window of AI-VMD setup menu.Supports "Demo screen display" on the [2. AI motion detection setting] window. 🇺 View details
Detection score can be displayed using the on/off switch on the demo screen.Changed the name of [Sensitivity setting] on the [4. Detailed setting] window as follows, for the operability improvement. 🇺 View details
Prior to this version: [Sensitivity setting]
This version or later: [Threshold setting]Improved the people tracking performance to enhance the detection accuracy. 🇺
Resolved Issues
Mask area does not work properly 🇨 (Added on Oct., 31, 2022)
Occurrence condition: Version 3.00 of this extension software