Released versions:

Click here for the version from V1.00 to V2.10.

...

This release note applies to the following models:

Version 1.00 or later

WV-S15700-V2LK

WV-S15500-V3LN

WV-S15700-V2LN

WV-S15500-V3LK

WV-S22500-V3L

WV-S22700-V2L

WV-S25700-V2LN

WV-S25500-V3LN

WV-S15600-V2LN

WV-S15500-V3LN1

WV-S22700-V2L1

WV-S22500-V3LG

WV-S25500-V3LG

WV-S22600-V2LG

WV-S25600-V2LG

WV-S22500-V3L1

WV-S22700-V2LG

WV-S25700-V2LG

WV-S25700-V2LN1

WV-S25500-V3LN1

WV-S15500-V3L

WV-S15700-V2L

WV-S25500-V3L

WV-S25600-V2L

WV-S25700-V2L

WV-S25600-V2LN

WV-S22600-V2L

WV-S15600-V2L

Version 1.02 or later

WV-S15500-F3L

WV-S22500-F3L

WV-S25500-F3L

Version 1.03 or later

WV-S15500-F6L

WV-S22500-F6L

WV-S25500-F6L

Priority Rank Level

🇦 : Recommended to apply
🇧 : When issue happened
🇨 : Maintenance timing
🇺 : Function / performance improvement

Anchor
V2.40
V2.40

Version 2.40

Release date: Sept 28, 2023 - Download the latest firmware
->Updated on Oct 31: Added an item written in red
SDK version: V1.60

New Features / Improvements

...

  • Corrected an issue where an mp4 video recorded on an SD memory card could not be played back on the camera. 🇨
    Occurrence condition: Record an mp4 video with [GOP control] set to "Advanced(Fixed GOP 60s w/1s key-frame)"

  • Corrected an issue where a communication error might occur on the connected i-PRO recorder on rare occasion. 🇨
    Occurrence condition: Start sequence display on the recorder while performing SD memory card recording on the camera.

  • Corrected an issue where the angle of view shifted after restarting the camera. 🇨
    Occurrence condition: Use digital zoom in to set the angle of view.

  • Corrected an issue where the [Save trigger] setting of SD memory recording might unexpectedly changed after firmware update. 🇨

  • Corrected an issue where the port of [Destination of Trap] was always the default value (162) in the actual operation, even when any other port number is set on the SNMP trap setting. 🇨

  • Corrected an issue where MQTT notification worked only when [AI analytics target] is set to "Other" for audio detection. 🇨

  • Corrected an issue where an unneccessary pop-up appeared. 🇨
    Occurrence condition: Set [Image capture size] to 3328x1872.

  • Corrected an issue where multi-screen live view might not show images from other cameras. 🇨

    Anchor
    V2.36
    V2.36

Version 2.36

...

  • Changed the company name in the GlobalSign digital certificate installed on the camera to "i-PRO Co., Ltd." 🇺

  • Supports the FTP function. 🇺 View details

  • Added the HTML initialization function. 🇺 (Added on Nov.11, 2022)
    [Load the default HTML files (setup menu).] and [Reset to the default and load the default HTML files.] have been added to the [Default reset] tab.

  • Changed the frame rate restriction when the extension software AI People Detection is installed on the camera as below. 🇺
    Previous versions : Restrict the maximum frame rate from 30fps to 15 fps when AI People Detection is installed on the camera.
    This version or later : Restrict the maximum frame rate from 30fps to 15fps after the communication starts with i-PRO Active Guard or i-PRO Configuration Tool.
    Note : The extension software AI People Detection needs to be updated to version 1.30 or later

...