Released versions:
Click here for the release note from V1.02 to V5.10
Priority Rank Level
🇦 : Recommended to apply |
Version 5.50
Release date: July 31, 2024
New Features / Improvements
Supports new cameras. 🇺
Corner camera: WV-X25580-F2LN2
Rapid PTZ: WV-S66300-Z3N, WV-S66300-Z3LN, WV-S66300-Z4N, WV-S66300-Z4LN, WV-S66600-Z3N, WV-S66600-Z3LN, WV-S66700-Z3N, WV-S66700-Z3LN, WV-X66300-Z3K, WV-X66300-Z3LK, WV-X66300-Z4K, WV-X66300-Z4LK, WV-X66600-Z3K, WV-X66600-Z3LK, WV-X66700-Z3K, WV-X66700-Z3LKEnhanced security. 🇺
Resolved Issues
Corrected an issue where login via web browser might fail after changing the [User management] setting. 🇨
Version 5.40
Release date: February 16, 2024
New Features / Improvements
Supports new cameras 🇺
Rapid PTZ: WV-X66700-Z3LS, WV-X66700-Z3S, WV-S66700-Z3L, WV-S66700-Z, WV-X66600-Z3LS, WV-X66600-Z3S, WV-S66600-Z3L, WV-S66600-Z3, WV-X66300-Z4LS, WV-X66300-Z3LS, WV-X66300-Z4S, WV-X66300-Z3S, WV-S66300-Z4L, WV-S66300-Z3L, WV-S66300-Z4, WV-S66300-Z3
X-series AI camera: WV-X15700-V2LN, WV-X15700-V2L, WV-X25700-V2LN, WV-X22700-V2L, X15600-V2LN, WV-X15600-V2L, WV-X25600-V2LN, WV-X22600-V2L, WV-X15500-V3LN, WV-X15500-V3L, WV-X25500-V3LN, WV-X22500-V3L, WV-X15300-V3LN, WV-X15300-V3L, WV-X25300-V3LN, WV-X22300-V3L
Compact dome: WV-X35402-F2L, WV-S35402-F2L, WV-S35402-F2LG, WV-S35402-F2L1, WV-S32402-F2L, WV-S32402-F2LG, WV-S32402-F2L1, WV-U35401-F2L, WV-U35401-F2LG, WV-U31401-F2L, WV-U31401-F2LG, WV-X35302-F2L, WV-S35302-F2L, WV-S35302-F2LG, WV-S35302-F2L1, WV-S32302-F2L, WV-S32302-F2LG, WV-S32302-F2L1, WV-U35301-F2L, WV-U35301-F2LG, WV-U31301-F2L, WV-U31301-F2LGAdded a [Active ClearSight] button to the “Camera control [Advanced]” panel for Rapid PTZ cameras. 🇺
Improved the stability of AI Privacy Guard recording by setting Stream(4) to 10ips. 🇺
Resolved Issues
Corrected an issue where the recorder could not be accessed from the browser, WV-ASM300 or i-PRO Mobile App, on rare occasion. 🇨
Occurrence conditions:
- Unstable network environment
- Use HTTPS to access the recorderCorrected an issue where the audio from camera would not be output. 🇨
Occurrence conditions:
- MJPEG recording
- [Connection] setting of the camera was set to “HTTPS” in the [Security] setting
- The camera supports TLS1.3Corrected an issue where recording data might not be played back on general viewer. 🇨
Occurrence conditions:
- Copy or download the recording data in MP4 format
- The data was recorded at the following resolution: 2192x2192, 1600x1200, 3072x2304, 3072x1728, 1728x3072, 1440x2560, 2160x3840, 1440x1440, 1200x1200, 3328x1872, 1872x3328, 2688x1520, or 1520x2688
Version 5.30
Release date: June 30, 2023
New Features / Improvements
Supports new cameras 🇺
- WV-U11300-V2, WV-U21300-V2L
- WV-S1136A, WV-S1536LA, WV-S1536LA-B, WV-S1536LNA, WV-S1536LNA-B, WV-S1536LNSA, WV-S1536LTA, WV-S1536LTNA, WV-S2136A, WV-S2136A-B, WV-S2136GA, WV-S2136GA-B, WV-S2136LA, WV-S2136LA-B, WV-S2136LGA, WV-S2136LGA-B, WV-S2236LA, WV-S2236LA-B, WV-S2236LGA, WV-S2236LGA-B, WV-S2536LA, WV-S2536LGA, WV-S2536LGNA, WV-S2536LNA, WV-S2536LTA, WV-S2536LTNA, WV-S4156A, WV-S4176A, WV-S4556LA,WV-S4576LA, WV-S71300A-F3Supports an RTSP response without session ID to the play command. 🇺
Supports a specific provider for e-mail transmission. 🇺
Improved ONVIF connection. 🇺
Added refreshing process to the recorder’s LCD for stable display. 🇺
Note: Due to this refreshing process, the characters on LCD and indicators will be turned off for a few seconds once a day.
Version 5.20
Release date: February 28, 2023
New Features / Improvements
Supports new cameras 🇺
- WV-S61300-ZY, S61300-ZYG, S61301-Z1, S65300-ZY, S65300-ZYG, S65301-Z1, S65301-Z1-1, S65301-Z1S, S65302-Z2, S65302-Z2G, S65302-Z2-1, S65340-Z2G, S65340-Z2N1, S65340-Z4G, S65340-Z4N1 View details #1
- WV-S61501-Z1, S65501-Z1, S65501-Z1G View details #2
- WV-X86530-Z2, X86531-Z2, X86530-Z2-1, X86531-Z2-1 View details #3
- WV-U85402-V2L, S85402-V2L, S85702-F3L, U85402-V2L1, S85402-V2L1, S85702-F3L1 View details #4
- WV-S1536LT View details #5Supports the ONVIF connection with ACTi encoder V2221 and V2224. 🇺 View details #6
Supports the new campany name in the digital certificate installed on i-PRO Network Camera. 🇺
Resolved Issues
Corrected an issue where the recorder may restart due to a recording error (RCA). 🇧
Occurrence condition: When satisfying both of the followings.
- Connection error occurs on all the cameras performing schedule recording
- Recording has not been performed for more than 70 minutes* on the camera for event recording
*140 minutes soon after the recorder startupCorrected an issue where the recorder may restart due to a defective HDD. 🇨
Occurrence condition: [HDD operation mode] is set to Single mode or Mirroring mode