Skip to end of metadata
Go to start of metadata

You are viewing an old version of this content. View the current version.

Compare with Current View Version History

« Previous Version 8 Next »

Released versions:

Click here for the release note from V1.00 to V2.11

This release note applies to the following models:

Version 1.00 or later

WV-S4556LM

WV-S4176

WV-S4556L

WV-S4156

WV-S4576LM

WV-S4576L

Priority Rank Level

🇦 : Recommended to apply
🇧 : When issue happened
🇨 : Maintenance timing
🇺 : Function / performance improvement

Version 2.23

Release date: December 9, 2022

Resolved Issues

  • The image becomes pinkish. 🇨
    Occurrence condition:
    When satisfying both of the following conditions:
    - [Day & Night(IR)] is set to "Auto":
    - The camera was restarted in the following steps:
    1. Turned off in black&white mode
    2. Turned on in a bright environment

  • SFTP transmission fails depending on the SFTP server to be connected. 🇨

  • The live image may not appear, as the maximum number of users concurrently accessible to the camera decreases. 🇧
    Occurrence condition:
    When satisfying all of the following conditions:
    - Version 2.10, 2.11 or 2.20
    - [Internet mode] is set to Off by CGI command
    - H.264/H.265 transmission

  • The camera may reboot. 🇨
    Occurrence condition:
    When satisfying both of the following conditions:
    - AI-VMD and AI Privacy Guard are enabled on the camera
    - Take a snap shot of the target stream for AI Privacy Guard "Blurring" or "Block"

  • Noise may appear on the camera title and date/time of On-Screen Display (OSD). 🇨
    Occurrence condition: When performing AI Privacy Guard "Blurring" or "Block" on the image

Version 2.20

Release date: September 30, 2022
SDK version: V1.60

New Features / Improvements

  • Changed the company name in the GlobalSign digital certificate installed on the camera to "i-PRO Co., Ltd." 🇺

  • Supports the FTP function. 🇺 View details

  • Added the HTML initialization function. 🇺 (Added on Nov.11, 2022)
    [Load the default HTML files (setup menu).] and [Reset to the default and load the default HTML files.] have been added to the [Default reset] tab.

Resolved Issues

  • The occupancy detection area information is not included in the HTTP alarm notification from the camera. 🇨

  • The frame rate and bit rate may not recover once they drop due to the environmental cause. 🇨