AI-VMD/AI People Counting for 360-degree fisheye camera

AI-VMD/AI People Counting for 360-degree fisheye camera

Released versions:

Click here for the release note from V1.00 to V1.30

Priority Rank Level

: Recommended to apply
: When issue happened
: Maintenance timing
: Function / performance improvement

Version 2.10

Release date: September 30, 2024

New Features / Improvements

  • Changed the font to NotoSans.
    *Camera firmware needs to be updated to the October 2024 release.

  • Added [Give priority to detection accuracy in recommended area] on/off setting.
    When On is selected, the detection accuracy in the center area will increase.
    *i-PRO Configuration Tool Version 4.1 or later is required.

  • Changed the maximum characters for [HTTP transmission] - [Destination address] from 63 to 128.

  • Updated external interface specifications.
    For details, refer to "AI-VMD/AI People Counting for 360-degree fisheye External Interface Specification (C0321)" on Technical Information.

Resolved Issues

  • Corrected the timestamp of aggregation data exported through [Data acquisition] - [Create a form] during the daylight savings time.

Version 2.00

Release date: May 30, 2024

New Features / Improvements

  • Changed the font on the browser setting window to NotoSans.

  • Support displaying detection frames on the demo screen in HTTPS connection.

  • Added an update to SSL communication.

  • Supports TLS1.3.

  • Added an improvement for Remote Monitoring linkage.

Resolved Issues

  • Corrected an issue where the MQTT transmission might fail.

Version 1.90

Release date: Feb 29, 2024

New Features / Improvements

  • Added [Alarm notification at the completion of detection] on/off setting to the [Common settings] View detail
    *i-PRO Configuration Tool Version 3.11 is required.

  • Updated external interface specifications.
    For details, refer to "AI-VMD/AI People Counting for 360-degree fisheye External Interface Specification (C0321)" on Technical Information.

  • Added 5s and 10s to the options of [The Interval for the transmission of ONVIF®].
    *i-PRO Configuration Tool Version 3.11 is required.

Version 1.70

Release date: Sept 28, 2023

New Features / Improvements

  • Supports new cameras.
    - WV-S4156A / S4176A / S4556LA / S4576LA / S4576LMA / S4556LMA

  • Improved the setting field on the demo screen. View details

  • Improved the process to reflect the application settings imported via i-PRO Configuration Tool (iCT) so that the camera does not need a reboot to reflect changes.

  • Supports 0.5s, 1s, 2s, 3s, and 4s of the [Alarm deactivation time] on camera’s setting.

  • Added "Cross Line Counting+Area Counting (i-PRO Remo. Service)*" to [Count data storage setting]-> [Target to store].
    -> Update on Nov 7, 2023:
    Changed the name from "Cross Line Counting+Area Counting (i-PRO Remo. Service)” to “Cross Line Counting+Area Counting (Format with 2-year storage)“
    *This option is available only in Japan. i-PRO Configuration Tool Version 3.9 is required.

Resolved Issues

Version 1.50

Release date: February 27, 2023

New Features / Improvements

  • Supports setting of detection line and detection area name. View details

  • Added [Measure score] on/off setting on the demo window to measure and display the maximum and minimum detection score of an object. View details

  • Added 5sec, 10sec and 15sec to the [Transmission interval] options of MQTT transmission and HTTP transmission settings. View details

  • Improved to send detection score to i-PRO Active Guard. This enabled the detection score display on i-PRO Active Guard.

  • Updated external interface specifications.
    For details, refer to "AI-VMD/AI People Counting for 360-degree fisheye External Interface Specification 【C0321】" on Technical Information.

Version 1.41

Release date: October 31, 2022

Resolved Issues

  • The area count incorrectly shows 1 detection in case of 0 detection, on i-PRO Active Guard.
    Occurrence condition: When using this extension software with i-PRO Active Guard.
    Note: This issue can occur on the 3rd party software that receives ONVIF EventStream from this extension software.

Version 1.40

Release date: September 26, 2022

Note before updating to this version :
Update i-PRO Configuration Tool to version 3.3* or later to apply the changes.
*To be released in the middle of October, 2022

New Features / Improvements

  • Supports MQTT alarm transmission. View details
    "Alarm notification" setting has been added to the [MQTT transmission] on the [Camera Advanced Setting] window of i-PRO Configuration Tool (iCT).

  • Supports "Demo screen display" on the [AI Video Motion Detection (AI-VMD)] setting in the [Camera Advanced Setting] window of i-PRO Configuration Tool(iCT). View details
    Detection score can be displayed using the on/off switch on the demo screen.

  • Divided the [Human identification sensitivity] setting into [Human identification threshold (head)] and [Human identification threshold (whole body)] in the [Common setting], for precise detection. View details

  • Improved the people tracking performance to enhance the detection accuracy.

Resolved Issues

  • Mask area does not work properly (Added on Oct., 31, 2022)
    Occurrence condition: Version 1.30 of this extension software

Related content

AI People Detection
AI People Detection
More like this
AI-VMD