The process of verification of communication between IP Server and IP Camera is crucial for the functioning of Failover Edge Recording. This step will help make troubleshooting easier in the event of an unlikely Edge Recording failure.


After the IP Server has restarted, open the camera’s Management interface within the internet browser window that was minimized at the end of Step 1:

On the left panel, select Setup.

On the Setup page, the green button labeled Basic should be highlighted by default. Select the SD Memory card tab at the top of the screen.


On the SD Memory card page, ensure the Use must be button is selected.

Overwrite must be On.


SD memory card information: Displays the Remaining capacity and the Execute button to format the installed SD Card.

Info

It is recommended to fully format the SD Card during the initial Edge Recording setup.

Image Added


Recording Stream 1:

This is set to The default value for the Recording Format is H.264 (1) by default. It is possible to select one of the four available H.264 settings.

Image Removed

The image above shows the first selection for H.264 configuration settings as an example. It is recommended to consult
Info

Consult the camera’s documentation

to understand

for more information on how this option affects the video captured

video

with Edge Recording.

SD memory card information: Format the
installed SD Card.
See Notes at the bottom for more information.

Image Removed

If the installed SD Card has never be formatted, it is recommended to perform a full format during the initial Edge Recording setup to ensure that video is captured.

This page provides an easy way Image Added

This page allows to determine if the IP Server has been successfully connected to the IP Camera with Failover Edge Recording enabled.

Verify that the Save Trigger (under Recording Stream 1) is greyed out and displays the phrase status Network failure.

Network Failure message should appear, confirming a successful connection with the IP Camera and Failover Edge Recording.
Note

If Network

Failure

failure message is not visible

now

, then IP server is not communicating with the camera. It is recommended

that

to remove the camera

be removed

from IP server and

that the be

reset it to its original factory condition; afterwards,

and then

repeat the

steps above

Communication Verification procedure.


If the Network Failurefailure message is visible, reboot a successful connection between the IP Camera and Failover Edge Recording has been established.

Reboot the camera following these steps:

Click on Maintenance (on the left).

Image RemovedImage Added

Select the Default reset tab.

Find Reboot from the list of options presented and then click Execute.

The reboot process takes should take about 2 minutes.


Note

Congratulations

,

: Edge Recording is now

successfully

configured

.

!